Voltage and power meter | |||||
This is a practical power meter for electricians; you can use it to calculate and install power | |||||
Cross-sectional area (mm2) | 220V | 380V | Cross-sectional area(mm2) | 220V | 380V |
1 square meter (8A) | 1800 | 2500 | 6 square meters (30A) | 7500 | 10000 |
1.5 square meters (12A) | 2800 | 3500 | 10 square meters (40A) | 10000 | 13000 |
2.5 square meters (16A) | 4000 | 4500 | 16 square meters (50A) | 13500 | 16500 |
4 square meters (20A) | 5000 | 6000 | 25 square meters (72A) | 18000 | 25000 |
Note: Depending on the usage environment, it is recommended to leave a slight margin as a buffer. The data is for reference only! | |||||
6/10KV | |||||
conductor nominal cross section | Insulation thickness | Sheath thickness | Approximate outer diameter of cable | DC resistance of wire | |
CU | AI | ||||
25 | 3.4 | 2.5 | 42 | 0.727 | 0.120 |
35 | 2.5 | 44 | 0.524 | 0.868 | |
50 | 2.5 | 46 | 0.387 | 0.641 | |
70 | 2.5 | 50 | 0.268 | 0.443 | |
95 | 3.0 | 54 | 0.193 | 0.320 | |
120 | 3.0 | 58 | 0.153 | 0.253 | |
150 | 3.0 | 62 | 0.124 | 0.206 | |
185 | 3.0 | 65 | 0.0991 | 0.164 | |
240 | 3.5 | 71 | 0.0754 | 0.125 | |
300 | 3.5 | 75 | 0.0601 | 0.100 | |
400 | 3.6 | 85 | 0.0470 | 0.0778 | |
500 | 3.7 | 95 | 0.0366 | 0.0605 | |
8.7/15KV | |||||
conductor nominal cross section | Insulation thickness | Sheath thickness | Approximate outer diameter of cable | DC resistance of wire | |
CU | AI | ||||
25 | 4.5 | 2.8 | 50 | 0.727 | 0.120 |
35 | 2.9 | 53 | 0.524 | 0.868 | |
50 | 2.9 | 55 | 0.387 | 0.641 | |
70 | 2.9 | 58 | 0.268 | 0.443 | |
95 | 3.3 | 63 | 0.193 | 0.320 | |
120 | 3.3 | 66 | 0.153 | 0.253 | |
150 | 3.6 | 70 | 0.124 | 0.206 | |
185 | 3.6 | 74 | 0.0991 | 0.164 | |
240 | 3.6 | 79 | 0.0754 | 0.125 | |
300 | 3.6 | 84 | 0.0601 | 0.100 | |
400 | 3.7 | 95 | 0.0470 | 0.0778 | |
500 | 3.9 | 102 | 0.0366 | 0.0605 | |
12/20KV | |||||
conductor nominal cross section | Insulation thickness | Sheath thickness | Approximate outer diameter of cable | DC resistance of wire | |
CU | AI | ||||
35 | 5.5 | 2.9 | 58 | 0.524 | 0.868 |
50 | 3.0 | 62 | 0.387 | 0.641 | |
70 | 3.1 | 66 | 0.268 | 0.443 | |
95 | 3.3 | 70 | 0.193 | 0.320 | |
120 | 3.4 | 73 | 0.153 | 0.253 | |
150 | 3.5 | 77 | 0.124 | 0.206 | |
185 | 3.6 | 81 | 0.0991 | 0.164 | |
240 | 3.8 | 87 | 0.0754 | 0.125 | |
300 | 3.9 | 92 | 0.0601 | 0.100 | |
400 | 4.1 | 100 | 0.0470 | 0.0778 | |
500 | 4.3 | 107 | 0.0366 | 0.0605 | |
26/35KV | |||||
conductor nominal cross section | Insulation thickness | Sheath thickness | Approximate outer diameter of cable | DC resistance of wire | |
CU | AI | ||||
50 | 10.5 | 3.8 | 87 | 0.387 | 0.641 |
70 | 3.9 | 91 | 0.268 | 0.443 | |
95 | 4.0 | 95 | 0.193 | 0.320 | |
120 | 4.1 | 98 | 0.153 | 0.253 | |
150 | 4.2 | 102 | 0.124 | 0.206 | |
185 | 4.4 | 106 | 0.0991 | 0.164 | |
240 | 4.5 | 112 | 0.0754 | 0.125 | |
300 | 4.7 | 117 | 0.0601 | 0.100 | |
400 | 4.9 | 125 | 0.0470 | 0.0778 | |
500 | 5.1 | 132 | 0.0366 | 0.0605 | |