Voltage and power meter | |||||
This is a practical power meter for electricians; you can use it to calculate and install power | |||||
Cross-sectional area (mm2) | 220V | 380V | Cross-sectional area(mm2) | 220V | 380V |
1 square meter (8A) | 1800 | 2500 | 6 square meters (30A) | 7500 | 10000 |
1.5 square meters (12A) | 2800 | 3500 | 10 square meters (40A) | 10000 | 13000 |
2.5 square meters (16A) | 4000 | 4500 | 16 square meters (50A) | 13500 | 16500 |
4 square meters (20A) | 5000 | 6000 | 25 square meters (72A) | 18000 | 25000 |
Note: Depending on the usage environment, it is recommended to leave a slight margin as a buffer. The data is for reference only! | |||||
6/10KV three-core cross-linked polyethylene insulated, polyvinyl chloride sheathed power cable | |||||||||
Nominal cross-sectional area of conductor (mm2) | Insulation thickness (mm) | Sheath thickness (mm) | Approximate outer diameter of cable (mm) | Approximate cable weight (kg/km) | DC resistance of conductor (Ω/km) | Cable current carrying capacity | |||
Directly buried in soil (A) | |||||||||
CU | AI | CU | AI | CU | AI | ||||
25 | 3.4 | 2.5 | 42 | 1895 | 1430 | 0.727 | 0.120 | 140 | 110 |
35 | 44 | 2293 | 1642 | 0.524 | 0.868 | 170 | 130 | ||
50 | 46 | 2812 | 1881 | 0.387 | 0.641 | 200 | 155 | ||
70 | 50 | 3508 | 2205 | 0.268 | 0.443 | 245 | 190 | ||
95 | 3.0 | 54 | 4402 | 2635 | 0.193 | 0.320 | 290 | 225 | |
120 | 58 | 5319 | 3087 | 0.153 | 0.253 | 330 | 225 | ||
150 | 62 | 6309 | 3518 | 0.124 | 0.206 | 370 | 285 | ||
185 | 65 | 7619 | 3877 | 0.0991 | 0.164 | 420 | 325 | ||
240 | 3.5 | 71 | 9218 | 4753 | 0.0754 | 0.125 | 480 | 380 | |
300 | 75 | 11159 | 5577 | 0.0601 | 0.100 | 545 | 430 | ||
400 | 3.6 | 85 | 15206 | 7617 | 0.0470 | 0.0778 | 632 | 491 | |
500 | 3.7 | 95 | 18463 | 8995 | 0.0366 | 0.0605 | 700 | 562 | |
8.7/15KV three-core cross-linked polyethylene insulated, polyvinyl chloride sheathed power cable | |||||||||
Nominal cross-sectional area of conductor (mm2) | Insulation thickness (mm) | Sheath thickness (mm) | Approximate outer diameter of cable (mm) | Approximate cable weight (kg/km) | DC resistance of conductor (Ω/km) | Cable current carrying capacity | |||
Directly buried in soil (A) | |||||||||
CU | AI | CU | AI | CU | AI | ||||
25 | 4.5 | 2.8 | 50 | 2537 | 2072 | 0.727 | 0.120 | 140 | 110 |
35 | 2.9 | 53 | 3985 | 2334 | 0.524 | 0.868 | 170 | 130 | |
50 | 55 | 3529 | 2598 | 0.387 | 0.641 | 200 | 155 | ||
70 | 58 | 4197 | 2895 | 0.268 | 0.443 | 245 | 190 | ||
95 | 3.3 | 63 | 5230 | 3462 | 0.193 | 0.320 | 290 | 225 | |
120 | 66 | 6120 | 3888 | 0.153 | 0.253 | 330 | 225 | ||
150 | 3.6 | 70 | 7207 | 4416 | 0.124 | 0.206 | 370 | 285 | |
185 | 74 | 8378 | 4935 | 0.0991 | 0.164 | 420 | 325 | ||
240 | 79 | 10177 | 5712 | 0.0754 | 0.125 | 480 | 380 | ||
300 | 84 | 12159 | 6577 | 0.0601 | 0.100 | 545 | 430 | ||
400 | 3.7 | 95 | 16192 | 8603 | 0.0470 | 0.0778 | 632 | 491 | |
500 | 3.9 | 102 | 19522 | 10055 | 0.0366 | 0.0605 | 700 | 562 | |
12/20KV three-core cross-linked polyethylene insulated, polyvinyl chloride sheathed power cable | |||||||||
Nominal cross-sectional area of conductor (mm2) | Insulation thickness (mm) | Sheath thickness (mm) | Approximate outer diameter of cable (mm) | Approximate cable weight (kg/km) | DC resistance of conductor (Ω/km) | Cable current carrying capacity | |||
Directly buried in soil (A) | |||||||||
CU | AI | CU | AI | CU | AI | ||||
35 | 55 | 2.9 | 58 | 3405 | 2754 | 0.524 | 0.868 | 170 | 130 |
50 | 3.0 | 62 | 4085 | 3136 | 0.387 | 0.641 | 200 | 155 | |
70 | 3.1 | 66 | 4939 | 3600 | 0.268 | 0.443 | 245 | 190 | |
95 | 3.3 | 70 | 5936 | 4132 | 0.193 | 0.320 | 290 | 225 | |
120 | 3.4 | 73 | 6880 | 4611 | 0.153 | 0.253 | 330 | 225 | |
150 | 3.5 | 77 | 8028 | 5182 | 0.124 | 0.206 | 370 | 285 | |
185 | 3.6 | 81 | 9312 | 5796 | 0.0991 | 0.164 | 420 | 325 | |
240 | 3.8 | 87 | 11271 | 6733 | 0.0754 | 0.125 | 480 | 380 | |
300 | 3.9 | 92 | 13392 | 7701 | 0.0601 | 0.100 | 545 | 430 | |
400 | 4.1 | 100 | 16840 | 9251 | 0.0470 | 0.0778 | 632 | 491 | |
500 | 4.3 | 107 | 20214 | 10747 | 0.0366 | 0.0605 | 700 | 562 | |
26/35KV three-core cross-linked polyethylene insulated, polyvinyl chloride sheathed power cable | |||||||||
Nominal cross-sectional area of conductor (mm2) | Insulation thickness (mm) | Sheath thickness (mm) | Approximate outer diameter of cable (mm) | Approximate cable weight (kg/km) | DC resistance of conductor (Ω/km) | Cable current carrying capacity | |||
Directly buried in soil (A) | |||||||||
CU | AI | CU | AI | CU | AI | ||||
50 | 10.5 | 3.8 | 87 | 6692 | 5744 | 0.387 | 0.641 | 200 | 155 |
70 | 3.9 | 91 | 7670 | 6331 | 0.268 | 0.443 | 245 | 190 | |
95 | 4.0 | 95 | 8770 | 6966 | 0.193 | 0.320 | 290 | 225 | |
120 | 4.1 | 98 | 9828 | 7558 | 0.153 | 0.253 | 330 | 225 | |
150 | 4.2 | 102 | 11105 | 8259 | 0.124 | 0.206 | 370 | 285 | |
185 | 4.4 | 106 | 12566 | 9051 | 0.0991 | 0.164 | 420 | 325 | |
240 | 4.5 | 112 | 14659 | 10120 | 0.0754 | 0.125 | 480 | 380 | |
300 | 4.7 | 117 | 17009 | 11317 | 0.0601 | 0.100 | 545 | 430 | |
400 | 4.9 | 125 | 20716 | 13127 | 0.0470 | 0.0778 | 632 | 491 | |
500 | 5.1 | 132 | 24321 | 14854 | 0.0366 | 0.0605 | 700 | 562 | |