Voltage and power meter | |||||
This is a practical power meter for electricians; you can use it to calculate and install power | |||||
Cross-sectional area (mm2) | 220V | 380V | Cross-sectional area(mm2) | 220V | 380V |
1 square meter (8A) | 1800 | 2500 | 6 square meters (30A) | 7500 | 10000 |
1.5 square meters (12A) | 2800 | 3500 | 10 square meters (40A) | 10000 | 13000 |
2.5 square meters (16A) | 4000 | 4500 | 16 square meters (50A) | 13500 | 16500 |
4 square meters (20A) | 5000 | 6000 | 25 square meters (72A) | 18000 | 25000 |
Note: Depending on the usage environment, it is recommended to leave a slight margin as a buffer. The data is for reference only! | |||||
Number of cores x Nominal conductor cross-section (mm2) | Nominal thickness (mm) | cable outer diameter (mm) | At 20°C, the maximum DC resistance between the ground conductor and the shielding layer is Ω/km. | |||
Power core | ground wire core | Control wire core | Power core insulation | jacket | ||
3x25 | 1x16 | 3x4 | 1.5 | 5.0 | 39.7~42.9 | 0.56 |
3x35 | 1x16 | 1.6 | 5.0 | 43.1~46.3 | 0.54 | |
3x50 | 1x25 | 1.7 | 5.3 | 48.5~51.8 | 0.44 | |
3x70 | 1x35 | 3x6 | 1.8 | 5.8 | 55.1~58.8 | 0.30 |
3x95 | 1x50 | 2.0 | 6.4 | 62.4~66.1 | 0.26 | |
3x120 | 1X50 | 3x10 | 2.2 | 6.9 | 68.0~72.5 | 0.24 |
3x150 | 1x70 | 2.4 | 7.3 | 74.5~79.5 | 0.23 | |
Number of cores*cross section (mm2) | Insulation thickness | Sheath thickness | cable outer diameter | Cable reference weight(km/kg) | Maximum current resistance of 20oC conductor (copper) | 25oC Rated Current Carrying Capacity (A) | |
Min. | Max. | ||||||
3x35+1x6+3x4 | 2.8 | 6.0 | 55.0 | 60.7 | 4600 | 0.565 | 135 |
1.24 | |||||||
5.09 | |||||||
3x50+1x25+3x6 | 2.8 | 6.0 | 57.8 | 63.0 | 4890 | 0.393 | 170 |
0.795 | |||||||
3.39 | |||||||
3x95+1x50+3x6 | 3.0 | 6.0 | 64.1 | 70.8 | 6680 | 0.277 | 205 |
0.565 | |||||||
3.39 | |||||||
3x120+1x70+3x6 | 3.0 | 6.5 | 69.0 | 78.0 | 9600 | 0.164 | 295 |
0.277 | |||||||
3.39 | |||||||
3x150+1x70+3x6 | 3.5 | 6.5 | 72.4 | 80.0 | 11088 | 0.132 | 320 |
0.277 | |||||||
3.39 | |||||||
3x185+1x95+3x6 | 3.5 | 6.5 | 76.4 | 82.0 | 12600 | 0.108 | 360 |
0.21 | |||||||
3.39 | |||||||